IT'S AS EASY AS 1-2-3 TO BUY YOUR METAL ROOF!

Make your next roof your last!
Explore our colorsTrim & accessories

QUICK VIEW

Ultra-LOK     5V-LOK     PBR-LOK     TCM-LOK     SL-LOK     SS-LOK     MS-LOK

Quality Profile Selections for Florida Metal Roofing

EVERY POPULAR STYLE IS AVAILABLE

Installing the right roof doesn’t stop with the best quality materials at Tri County Metals—we strive to provide our customers with a large selection of the most popular styles for your beautiful new roof. Once our metal coils have been manufactured out of durable metals with quality paints, our customers choose from available crimps to provide exactly the roof you want for your home or building.

Click for full list of FL Product Approval code sheets

Click code number to view full product approval sheet for print or download.

ULTRA-LOK

26Ga. Ultra-Lok Roof Panel over 15/32″ Plywood
Florida Product Approval # 4595.16
Minimum 29 Ga. Ultra-Lok Roof Panel over 15/32″ Plywood
Florida Product Approval # 4595.17
Minimum 29 Ga. Ultra-Lok Roof Panel over 1×4 Wood Purlins Screwed over 15/32″ Plywood
Florida Product Approval # 4595.18
Minimum 29 Ga. Ultra-Lok Roof Panel over 1×4 Wood Purlins Nailed over 15/32″ Plywood
Florida Product Approval # 4595.19
Minimum 29 Ga. Ultra-Lok Roof Panel over OSB
Florida Product Approval # 4595.20
Minimum 29 Ga. Ultra-Lok Roof Panel over Shingles over 15/32″ Plywood
Florida Product Approval # 4595.21
Minimum 29 Ga. Ultra-Lok Roof Panel over 1×4 Wood Fastened Through-the-Rib
Florida Product Approval # 4595.22
Minimum 29 Ga. Roof Panel over 5′ OC Open Framing Steel Purlin
Florida Product Approval # 9903.3

5V-LOK

Min. 26 Ga. 5V-Lok Roof Panel, through fastened, over 15/32″ thick Plywood
Florida Product Approval #26000.1
Min. 26Ga. 5V-Lok Roof Panel over 15/32″ Plywood
Florida Product Approval # 4595.1
Min. 26Ga. 5V-Lok Roof Panel over 1×4 Wood Purlins over 15/32″ Plywood
Florida Product Approval # 4595.2

PBR-LOK

Min. 26Ga. PBR-Lok Roof Panel over 15/32″ Plywood
Florida Product Approval # 4595.10
Min. 26Ga. PBR-Lok Roof Panel over 1×4 Wood Purlins over 15/32″ Plywood
Florida Product Approval # 4595.11
26Ga. PBR-Lok Roof Panel over 5′ OC Open Framing
Florida Product Approval # 9903.2
26 Ga. PBR-Lok Wall Panel over 5′ OC Steel Purlin
Florida Product Approval # 9901.1

TCM-LOK

26 Ga TCM-LOK Panel over shingles (optional) over 15/32″ plywood
Florida Product Approval # 4595.5
24 Ga. TCM-LOK Panel over shingles (optional) over 15/32″ plywood
Florida Product Approval # 4595.6

SL-LOK

24 Ga.1 1/2″ SL-Lok Panel over 15/32″ plywood
Florida Product Approval # 4595.12

SS-LOK

24 Ga.1 1/2″ SS-Lok Panel over 22 Ga. Steel Deck
Florida Product Approval # 4595.13

MS-LOK 1.5″ Panel Approvals

Min. 24 Ga. Roof Panel over 15/32 Plywood
Florida Product Approval #4595.6
Coastal Series .032″ Aluminum Roof Panel over 15/32 Plywood
Florida Product Approval #4595.3

MS-LOK 2″ Panel Approvals

Min 24 Ga. Roof Panel over 22 Ga. Steel Deck
Florida Product Approval #4595.7
Min. 24 Ga. Roof Panel over 2′ / 5′ OC Open Framing Steel Purlin
Florida Product Approval #9903.1
Coastal Series .032″ Aluminum Roof Panel Over 22 Ga. Steel Deck
Florida Product Approval #4595.4

Which panel type is right for you?

Exposed Fastener vs. Standing Seam

We have several metal roofing panel styles to choose from from the classic 5V-LOK to the bold 1 3/4″ SS-LOK standing seam. There are, of course aesthetic considerations as far as which style of panel will look best on your existing home or new site built home. There is also the choice of exposed fastener panel system vs. standing seam. With an exposed fastener panel, the screws that fasten the panels to the roof deck are visible. These panel systems are lower cost in the panels and, typically, the labor to install them. The other choice is standing seam. If you are looking for clean lines and don't want the fasteners to be visible, then standing seam is likely the choice for you. Beyond the visual aspects afforded by standing seam panels, since the fasteners are concealed under the panel, there is much less possibility for water intrusion over time with screws moving with the contraction and expansion of the roof deck with the temperature fluctuation experienced in Florida's harsh weather environment. Explore all of our panel offerings below.

Is your project near the coast?

Our Aluminum Panel Options are likely right for you!

Florida's beach waters have a higher salt content than most US beaches. The sea water around Florida can be a challenge for coastal homes. Within 1,500 feet of the coast, most other roofing panels aren't even covered by warranty by other manufacturers. Our aluminum Coastal Series panels are covered by a a 25 year limited warranty and are perfect for coastal applications. Also, our warranty includes no setback restrictions.

Exposed Fastener Style Metal Roofing Panels

ULTRA-LOK Metal Roofing Panel Profile

Suitable for any roof with a pitch greater than 2/12.

Ultra-Lok Metal Roofing Panel Overview

This panel is manufactured in our facility.

  • Applications: Residential, Agricultural, Light Commercial, Industrial
  • Gauge: 26 gauge and 29 gauge residential, Agricultural, Light Commercial, Industrial
  • Panel Profile: 36″ Net coverage, 5 ribs 9″ On-Center, 3/4 high rib
  • Substrate: Galvalume® steel sheet, AZ 50 and AZ 55, conforming to ASTM A792
  • Finish: Siliconized Modified Polyester. Bare AZ55 Acrylic Galvalume®
  • Warranty: Galvalume® – 25 years and 6 months. Painted – 40 years

 

Florida Product Approvals for Ultra-Lok Metal Roofing Panels

The addition of these new Florida Product Approvals adds great versatility for our homeowner and contractor customers as they work on a variety of project types and circumstances. If you have any questions or need additional documentation, do not hesitate to contact us.

26Ga. Ultra-Lok Roof Panel over 15/32″ Plywood
Florida Product Approval # 4595.16
Minimum 29 Ga. Ultra-Lok Roof Panel over 15/32″ Plywood
Florida Product Approval # 4595.17
Minimum 29 Ga. Ultra-Lok Roof Panel over 1×4 Wood Purlins Screwed over 15/32″ Plywood
Florida Product Approval # 4595.18
Minimum 29 Ga. Ultra-Lok Roof Panel over 1×4 Wood Purlins Nailed over 15/32″ Plywood
Florida Product Approval # 4595.19
Minimum 29 Ga. Ultra-Lok Roof Panel over OSB
Florida Product Approval # 4595.20
Minimum 29 Ga. Ultra-Lok Roof Panel over Shingles over 15/32″ Plywood
Florida Product Approval # 4595.21
Minimum 29 Ga. Ultra-Lok Roof Panel over 1×4 Wood Fastened Through-the-Rib
Florida Product Approval # 4595.22
Minimum 29 Ga. Roof Panel over 5′ OC Open Framing Steel Purlin
Florida Product Approval # 9903.3

Ultra-LOK Brochure

5V-LOK Metal Roofing Panel Profile

5V-Lok Metal Roofing panels have a classic look matching one of the oldest profiles on the market.

Available in 26 Gauge only.

5V-Lok Metal Roofing Panel Overview

  • Applications: Residential, Agricultural
  • Gauge: 26 gauge
  • Panel Profile: 24″ Net Coverage
  • Substrate: Galvalume® steel sheet, AZ 55, conforming to ASTM A792
  • Finish: Galvalume® steel sheet, AZ55, conforming to ASTM A792
  • Warranty: Galvalume® – 25 years and 6 months

Available in: Flat, Ribbed, or Striated

Florida Product Approvals for 5V-Lok Metal Roofing Panels

Tri County Metals 5V-Lok metal roofing profile is now approved in Florida for installation over plywood using 1×4 wood purlins. The addition of these new Florida Product Approvals adds great versatility for our homeowner and contractor customers as they work on a variety of project types and circumstances. If you have any questions or need additional documentation, do not hesitate to contact us.

Min. 26 Ga. 5V-Lok Roof Panel, through fastened, over 15/32″ thick Plywood
Florida Product Approval #26000.1
Min. 26Ga. 5V-Lok Roof Panel over 15/32″ Plywood
Florida Product Approval # 4595.1
Min. 26Ga. 5V-Lok Roof Panel over 1×4 Wood Purlins over 15/32″ Plywood
Florida Product Approval # 4595.2

5V-LOK Brochure

PBR-LOK Metal Roofing Panel Profile

Suitable for any roof with a pitch greater than 1/2 / 12

Tri County Metals PBR-Lok Metal Roofing Panels are the most popular commercial panel on the market. Available in 26 Gauge and 24 Gauge.

5V-Lok Metal Roofing Panel Overview

  • Applications: Residential, Agricultural, Light Commercial, Industrial
  • Gauge: 26 gauge and 24 gauge
  • Panel Profile: 36″ Net Coverage, 4 ribs 12″ On-Center, 1 1/4″ high rib
  • Substrate: Galvalume® steel sheet, AZ 50 and AZ 55, conforming to ASTM A792
  • Finish: Siliconized Modified Polyester. Bare AZ55 Acrylic Galvalume®
  • Warranty: Galvalume® – 25 years and 6 months. Painted – 40 years

 

 

Florida Product Approvals for PBR-Lok Metal Roofing Panels

Tri County Metals PBR-Lok metal roofing profile in now approved in Florida for installation over “open framing”, plywood and using 1×4 wood purlins. The addition of these new Florida Product Approvals adds great versatility for our homeowner and contractor customers as they work on a variety of project types and circumstances. If you have any questions or need additional documentation, do not hesitate to contact us.

Min. 26Ga. PBR-Lok Roof Panel over 15/32″ Plywood
Florida Product Approval # 4595.10
Min. 26Ga. PBR-Lok Roof Panel over 1×4 Wood Purlins over 15/32″ Plywood
Florida Product Approval # 4595.11
26Ga. PBR-Lok Roof Panel over 5′ OC Open Framing
Florida Product Approval # 9903.2
26 Ga. PBR-Lok Wall Panel over 5′ OC Steel Purlin
Florida Product Approval # 9901.1

PBR-LOK Brochure

Hidden Fastener Style Metal Roofing Panels

Note: TCM-LOK is available in both 1″ and 1.5″ seam heights.

TCM-LOK Metal Roofing Panel Profile

Suitable for any roof with a pitch greater than 1/4″ /12.

The most popular residential standing seam metal roofing panel on the market today. The panel screws are actually concealed underneath the panel and are not visible. That is what makes this panel unique. Available in 24 Gauge.

TCM-LOK Metal Roofing Panel Overview

  • Applications: Residential and light commercial
  • Gauge: 24 or 26 Gauge, .032 or .040 Aluminum
  • Panel Profile: 15.75″ wide with 1″ high ribs
  • Substrate: 15/32″ plywood
  • Finish: Kynar, Galvalume
  • Warranty: 35-year limited paint warranty, 25-year Galvalume warranty, 25-Year Aluminum No Set Back Warranty

Available in: Flat, Ribbed, or Striated

Florida Product Approvals for TCM-LOK Metal Roofing Panels

The addition of these new Florida Product Approvals adds great versatility for our homeowner and contractor customers as they work on a variety of project types and circumstances. If you have any questions or need additional documentation, do not hesitate to contact us.

24 Ga Roof Panel over 15/32 Plywood
Florida Product Approval #4595.8

26 Ga Roof Panel over 7/16 OSB or 15/32 Plywood
Florida Product Approval #23302.1

TCM-LOK 1″

26 Ga Roof Panel over 15/32 Plywood
Florida Product Approval #4595.14

24 Ga Roof Panel over 15/32 Plywood
Florida Product Approval #4595.15

Coastal Series .032 Aluminum Roof Panel over 7/16 OSB or 15/32″ Plywood
Florida Product Approval # 4595.5

TCM-LOK 1.5″

24 Ga Roof Panel over 15/32 Plywood
Florida Product Approval #4595.9

TCM-LOK Brochure

SL-LOK Metal Roofing Panel Profile

SL-LOK Metal Roofing Panel Overview

  • Gauge: 24 Gauge
  • Panel Coverage: 15 1/2″
  • Rib Height: 1 1/2″
  • Minimum Slope: 1/4:12
  • Substrate: 15/32″ Plywood
  • Category: Standing Seam

Available in: Flat, Ribbed, or Striated

Florida Product Approvals for SL-LOK Metal Roofing Panels

The addition of these new Florida Product Approvals adds great versatility for our homeowner and contractor customers as they work on a variety of project types and circumstances. If you have any questions or need additional documentation, do not hesitate to contact us.

24 Ga.1 1/2″ SL-Lok Panel over 15/32″ plywood
Florida Product Approval # 4595.12

SL-LOK Brochure

SS-LOK Metal Roofing Panel Profile

This panel is roll formed on the job site.

SS-LOK Metal Roofing Panel Overview

  • Applications: Residential. Light Commerical
  • Gauge: 24 Gauge
  • Minimum Slope: 1/4:12 – Tube sealant recommended on pitches below 2 / 12
  • Panel Profile: 15 1/2″ net coverage, substrate Galvalume® steel sheet, conforming to ASTM A792
  • Finish Mill Finish AZ55 Acrylic Coated Galvalume®; 25 year limited warranty
  • TCM exlusive paint systems:
    • Core Defender Paint System® 40 / 30 year limited warranty
    • Max Defender Paint System® 35 / 30 year limited warranty
    • Coastal Defender Paint System® 25 year limited warraty

Available in: Flat, Ribbed, or Striated

Florida Product Approvals for SS-LOK Metal Roofing Panels

The addition of these new Florida Product Approvals adds great versatility for our homeowner and contractor customers as they work on a variety of project types and circumstances. If you have any questions or need additional documentation, do not hesitate to contact us.

24 Ga.1 1/2″ SS-Lok Panel over 22 Ga. Steel Deck
Florida Product Approval # 4595.13

SS-LOK Brochure

MS-LOK Metal Roofing Panel Profile

This panel is roll formed on the job site.

MS-LOK Metal Roofing Panel Overview

  • Gauge: 24 Gauge
  • Panel Coverage: 14 3/4″
  • Rib Height: 2″
  • Minimum Slope: 1/4:12
  • Substrate: Open steel framing
  • Options: Flat, Ribbed, or Striated
  • Category: Standing Seam

 

 

Note: MS-LOK is available in both 1.5″ and 2″ seam heights.

Florida Product Approvals for MS-LOK Metal Roofing Panels

The addition of these new Florida Product Approvals adds great versatility for our homeowner and contractor customers as they work on a variety of project types and circumstances. If you have any questions or need additional documentation, do not hesitate to contact us.

MS-LOK 1.5″ Panel Approvals

Min. 24 Ga. Roof Panel over 15/32 Plywood
Florida Product Approval #4595.6
Coastal Series .032″ Aluminum Roof Panel over 15/32 Plywood
Florida Product Approval #4595.3

MS-LOK 2″ Panel Approvals

Min 24 Ga. Roof Panel over 22 Ga. Steel Deck
Florida Product Approval #4595.7
Min. 24 Ga. Roof Panel over 2′ / 5′ OC Open Framing Steel Purlin
Florida Product Approval #9903.1
Coastal Series .032″ Aluminum Roof Panel Over 22 Ga. Steel Deck
Florida Product Approval #4595.4

GET A QUOTE NOW!